Redundancy of the lhc machine protection systems in case of magnet failures

Tesis doctoral de Andrés Gómez Alonso

The large hadron collider (lhc) built at cern, the european laboratory for particle physics will accelerate high  intensity proton beams up to an energy of 7 tev per proton. the energy stored in the lhc magnets reaches about  10ugj and each of   the proton beams stores about 360 mj at  nominal collision energy. accidental  release of   this  energy  in an uncontrolled way would  lead  to serious damage of   the accelerator  equipment.  the lhc machine  protection systems are designed to protect the accelerator against such uncontrolled release of the stored energy.  they provide constant monitoring of critical equipment, constant monitoring of the beam position and losses, a very  reliable beam dump system and  fast,  very  reliable  interlock systems  to  transmit  protection critical  signals.  while  protecting the accelerator in case of failure, the machine protection systems must also ensure maximum operational  availability of the lhc beams. magnet   failures produce  the  fastest  effects on  the beam and are most  critical  with respect   to machine protection.  quenches  (loss of  magnet  superconductivity)  and  failures of   the power  converters  (powering  failures)  have been  considered. these failures produce a current decay in the magnet and the corresponding decay in the magnetic field.  the current decay after a quench has been modeled by a gaussian curve based on previous studies. the current  decay generated by powering failures has been considered exponential. in order to evaluate the effects of magnet failures on the beam, particle tracking with variable magnetic fields has been  done using  the madx program.  dipole  failures produce a closed orbit  distortion  that  can be easily determined  analytically. losses produced by dipole failures are generally localized. quadrupole failures lead to beta beating and  tune shift, which in the transverse plane translate into either defocusing or displacement of the beam. the crossing of non­linear resonances induced by the  tune shift can generate losses of up to 10% of the beam intensity, and beam losses induced by quadrupole failures  may be distributed over many locations. the  transverse distribution of   the primary  losses at   the collimators can be described by a  function of  exponential  nature,  allowing a  fast  characterization of   the  impact   from  the parameters of   the  function.  dipole and quadrupole  failures lead to primary impacts that are not significantly different in shape or size, and in both cases faster failures  produce broader impacts. the average impact parameter for the cases studied ranges from less than 5 ¿m to about  1umm. the amount of losses reaching the superconducting elements from particles scattered after a primary impact is  greater for impacts at collimators outside or at the end of the cleaning insertions. it may reach up to 10% of the beam  intensity at  450 gev and 1% at  7 tev and  in most  cases,   it  decreases with  increasing  impact  parameter  of   the  primary impact.  with circulating beam at lhc, powering failures of the d1 dipoles at ir1 and ir5 produce the fastest losses both at  450 gev and 7 tev, reaching the damage level in less than 3 ms in both cases. other failures of normal conducting  magnets could produce damage after about 10 ms and quenches in the main superconducting dipoles may lead to  damage about 15 ms after the current decay starts. redundancy is ensured when, for a given failure, at least two  independent protection systems react on time. the beam loss monitors are able to request a beam dump in time for  every failure case considered. in combination with the quench protection system, the powering interlock controller  and the fast magnet current change monitors most failure cases are redundantly protected. only quenches of some  superconducting dipoles are not   redundantly protected with  these  systems,  but   redundancy can be ensured by  additional systems, such as a fast beam current monitor.

 

Datos académicos de la tesis doctoral «Redundancy of the lhc machine protection systems in case of magnet failures«

  • Título de la tesis:  Redundancy of the lhc machine protection systems in case of magnet failures
  • Autor:  Andrés Gómez Alonso
  • Universidad:  Politécnica de catalunya
  • Fecha de lectura de la tesis:  17/04/2009

 

Dirección y tribunal

  • Director de la tesis
    • Francisco Calviño Tavares
  • Tribunal
    • Presidente del tribunal: Luis García tabares
    • mathias Vogt (vocal)
    • bernhard Holzer (vocal)
    • Antonio Vergara fernández (vocal)

 